1.
Article | IMSEAR | ID: sea-219287

ABSTRACT

Background: Percutaneous device closure of atrial septal defect (ASD) has become an increasingly popular procedure as it offers several advantages. However, it is associated with infrequent, but life?threatening complications such as device embolization. Objective: To analyze the risk factors, common sites of embolization, associated complications, timing of embolization, and the treatment executed. Settings and Design: A retrospective study was performed at a tertiary referral center for cardiac services. Material and Methods: Pre?procedure, intra?procedure, and post?procedure data of patients whose ASD device embolized was collected retrospectively and analyzed for risk factors, common sites of embolization, associated complications, timing of embolization, and the treatment executed. Results: Thirty devices were embolized, out of which 13 were retrieved percutaneously in the Catheter laboratory, whereas 17 patients underwent surgery. Fourteen patients had an unfavorable septal morphology for device closure. Ten devices were embolized in the catheter laboratory, five in the intensive care unit, and two in the ward. The devices were embolized to almost all chambers of the heart and great vessels. One patient had an inferior vena cava rim tear while attempting percutaneous retrieval. One patient required a short period of total circulatory arrest (TCA) for retrieval of the device from ascending aorta, while another required a lateral position for retrieval from descending aorta. One patient required re?exploration for bleeding, while another had an air embolism and succumbed. Conclusions: Once embolization occurs, the risks associated increase manifold. Most of the surgical extractions are uneventful; however, there could be certain complications that may need repair of valvular apparatus, the institution of TCA, or the need for the lateral position. Air embolization though very rare can occur which could be fatal.

2.
Article | IMSEAR | ID: sea-219283

ABSTRACT

Background:Transesophageal echocardiography (TEE) probe insertion may be associated with many complications. Demographic factors and airway conditions such as high Mallampati scores (MMC) and Cormack-Lehane grades (MCLG) are likely to have an impact on its ease of insertion. The primary aim of this study was to identify the predictive factors for difficult real-time-three-dimensional TEE probe insertion. Methods: A total of 153 adult patients undergoing cardiac surgery were prospectively evaluated. The upper airway manipulations required for TEE probe placement were jaw thrust, reverse Sellick抯 maneuver, and laryngoscopy. All the patients who required airway manipulations were grouped under difficult TEE probe placement group. We evaluated the patients� predictive factors such as demographic characteristics and factors related to difficult intubation. Results: Out of 153 patients, 123 were males and 30 were females. Overall, 27.5% (n = 42) patients had difficulty in probe placement. About 31.7% (n = 39) males had difficulty in TEE probe placement against 13% (n = 4) females (P?value 0.045). Difficulty in TEE probe placement was found in 72.7% (n = 16) of obese patients (body mass index [BMI] > 30), compared to 18.6% (n = 17) in the patients with BMI less than 25 (P-value < 0.001). Probe insertion was significantly more difficult in the presence of MMC III and IV (50%, n = 18) compared to class I (19.2%, n = 10) (P?value 0.001) and MCLG III (73.3%, n = 22) compared to grade I (11.1%, n = 7) (P-value 0.001). Conclusion: Male gender, obesity, higher grades of MMC and MCLG were found to be the risk factors for difficult TEE probe placement in anesthetized patients.

3.
Rev. bras. cir. cardiovasc ; 37(2): 185-193, Apr. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1376509

ABSTRACT

Abstract Introduction: Type A acute aortic dissection (AAD) remains a challenging cardiac emergency despite the availability of various management strategies. This study compared the outcomes of supracoronary ascending aortic replacement (SCAAR) with aortic valve (AV) resuspension with those of modified Bentall's operation for type A AAD and the progression of aortic regurgitation (AR), long-term dilatation of aortic root and proximal arch, and long-term mortality in SCAAR patients. Methods: Sixty patients underwent surgery for type A AAD (January 2005 to December 2015). Forty-three patients underwent SCAAR with AV resuspension and 17 underwent modified Bentall's operation. All patients were followed up. Results: Upon follow-up of SCAAR patients (n=40), there was significant reduction in aortic root size (preoperative 39.3 mm [9.4] vs. postoperative 33.1 mm [9.1]; P<0.001). Three of these patients worsened to severe AR while others had similar or lesser degree of AR. On comparison between preoperative and postoperative dimensions of all patients (n=53), there was no significant difference in distal ascending aorta size (35.7 mm [8.1] vs. 34.4 mm [8.9]; P=0.52). However, an increase in descending thoracic aorta size (28.8 mm [7.8] vs. 33.7 mm [9.9]; P<0.001) was observed. In-hospital and late mortalities for SCAAR vs. modified Bentall's procedure were 11.7% (seven patients) (7% [3] vs. 23.5% [4]) and 28% (15 patients) (15% [6] vs. 69% [9]), respectively. Conclusion: SCAAR with AV resuspension is a safe surgical option for type A AAD. Preservation of AV is associated with better long-term outcomes and reduced mortality. Modified Bentall's operation may be associated with long-term mortality.

4.
Rev. bras. cir. cardiovasc ; 32(4): 338-340, July-Aug. 2017. tab, graf
Article in English | LILACS | ID: biblio-897932

ABSTRACT

Abstract Double orifice left atrioventricular valve (DOLAVV) or double orifice mitral valve (DOMV) is a rare congenital cardiac anomaly manifesting either as an isolated lesion (mitral stenosis or mitral insufficiency) or in association with other congenital cardiac defects. Signs of mitral valve disease are usually present along with the symptoms of associated coexistent congenital heart diseases. Mitral insufficiency due to annular dilatation is seen when DOLAVV is associated with endocardial cushion defects. Surgical intervention like mitral valve repair or replacement is required in 50% of patients and yields good results. We report a case of a 56-year-old lady who successfully underwent surgical correction of DOLAVV with partial atrioventricular canal defect.


Subject(s)
Humans , Female , Middle Aged , Endocardial Cushion Defects/surgery , Heart Septal Defects/surgery , Mitral Valve/abnormalities , Treatment Outcome , Heart Valve Prosthesis Implantation/methods , Endocardial Cushion Defects/complications , Mitral Valve Annuloplasty/methods , Heart Septal Defects/complications , Mitral Valve/surgery
6.
Ann Card Anaesth ; 2015 Oct; 18(4): 579-583
Article in English | IMSEAR | ID: sea-165271

ABSTRACT

We report an incident of detection of a free‑floating thrombus in the left ventricle (LV) using intraoperative two‑dimensional (2D) and three‑dimensional (3D) transesophageal echocardiography (TEE) during proximal coronary artery bypass graft anastomosis. A 58‑year‑old man presented to us with a 6‑month history of chest pain without any history suggestive of myocardial infarction or transient ischemic attacks. His preoperative echocardiography revealed the systolic dysfunction of LV, mild hypokinesia of basal and mid‑anterior wall, and the absence of an aneurysm. He was scheduled for on‑pump coronary artery bypass surgery. On intraoperative TEE before establishing cardiopulmonary bypass (CPB), a small immobile mass was found attached to LV apical area. After completion of distal coronary artery grafting, when the aortic cross‑clamp was removed, the heart was filled partially and beating spontaneously. TEE examination using 2D mode revealed a free‑floating mass in the LV, which was suspected to be a thrombus. Additional navigation using biplane and 3D modes confirmed the presence of the thrombus and distinguished it from papillary muscles and artifact. The surgeon opened the left atrium after re‑establishing electromechanical quiescence and removed a thrombus measuring 1.5 cm × 1 cm from the LV. The LV mass in the apical region was no longer seen after discontinuation of CPB. Accurate TEE‑detection and timely removal of the thrombus averted disastrous embolic complications. Intraoperative 2D and recent biplane and 3D echocardiography modes are useful monitoring tools during the conduct of CPB.